Coleman Electronics has installed & maintained a comprehensive range of Emergency Lighting Systems technology for many of our customers over the last number of years and we have extensive experience in the latest emergency lighting systems technology available on the market.

Review our Emergency Lighting Systems section which covers a broad spectrum of applications including Conventional Emergency Lighting & Addressable Emergency Lighting for detailed information relating to the services we provide at Coleman Electronics and determine which applications are best suited to meet your requirements.

Conventional

Conventional

In the event of a power failure on a premises it is important that the exit routes are well illuminated to allow safe egress from the building. There are strict regulatory requirements laid down in IS3217:2013 – the Irish emergency lighting standard as published by the NSAI.

Coleman Electronics offers the following Emergency Lighting Services:

  • Design Emergency Lighting Systems
  • Install Emergency Lighting Systems
  • Commission Emergency Lighting Systems
  • Maintain Emergency Lighting Systems

Every building owner has a legal obligation to ensure that the emergency lighting on their premises is fit for purpose and is designed, installed and maintained to the appropriate standard. IS3217:2013 indicates the minimum level of competency and experience that a system designer must have to certify a system.

Conventional Emergency Lighting systems incorporate a Manual Central Test Unit located at the fuse board / consumer unit where a test button is available for easy way to test the system. Once the emergency lighting circuits have been wired back to the CTU then this is an easy way to operate the system.

Conventional Fittings Include:

  • Room Emergency Lights
  • Escape Route Signs
  • Warehouse Spot Lights
  • Combined LED & Emergency Lighting Fittings
  • External Emergency Lighting Fittings

Emergency Lighting Design – Considerations:

  • Escape route signs
  • Stairs so each flight receives direct light
  • Changes in floor level
  • Changes in escape route direction
  • Corridor intersections
  • First aid posts
  • Fire alarm call points or fire fighting equipment
  • Outside the final exit door and to a place of safety
  • Moving stairways and walkways
  • Toilet facilities exceeding 8m2
  • Toilet facilities for disabled use
  • Motor generator, control and plant rooms
  • All areas [not mentioned] deemed by Risk Assessment
  • Manual release controls for electronically locked doors
  • Escape equipment for disable people
  • Refuges and call points

Coleman Electronics Ltd carry out audits on existing systems and can provide annual and quarterly maintenance contracts to satisfy the owners statutory obligations for the maintenance of the emergency lighting systems on their premises.

Contact us on T: + 353 96 72858 or E: info@colemangroup.ie and one of our highly experienced team will advise you on the range of Conventional Emergency Lighting Systems available designed to meet your requirements.

Addressable

Addressable

Under Irish law, strict regulatory requirements are set out in Emergency Lighting standard IS3217:2013 as published by the NSAI. It is essential that all exit routes are well illuminated to allow safe escape from a building in the event of a power failure.

Coleman Electronics offers the following Emergency Lighting Services:

  • Design Emergency Lighting Systems
  • Install Emergency Lighting Systems
  • Commission Emergency Lighting Systems
  • Maintain Emergency Lighting Systems

There is a legal obligation to ensure that the emergency lighting on every building is fit for purpose and therefore should be designed, installed, commissioned and maintained to the appropriate standard IS3217:2013. This standard indicates the minimum level of competency and experience that a system commissioner must have to certify a system.

Addressable Emergency Lighting systems incorporate a Central Control Panel with low voltage cable wiring out to every emergency lighting devices. The central control panel which is located near the fuse board unit where an Audited Test Button located on the Smart Panel that which is used to test the Emergency Lighting System as per IS3217:2013 guidelines.

This can be a Manual or Automatic process of testing the system. A paper report can be used to monitor faults and ease of certification by service engineers. Addressable emergency lighting systems show when a fitting is at end of life.

Addressable emergency lighting fittings include:

  • Room emergency lights
  • Escape route signs
  • Warehouse spot lights
  • Combined LED & emergency lighting fittings
  • External emergency lighting fittings

Emergency Lighting Design – Considerations:

  • Escape route signs
  • Stairs so each flight receives direct light
  • Changes in floor level
  • Changes in escape route direction
  • Corridor intersections
  • First aid posts
  • Fire alarm call points or fire fighting equipment
  • Outside the final exit door and to a place of safety
  • Moving stairways and walkways
  • Toilet facilities exceeding 8m2
  • Toilet facilities for disabled use
  • Motor generator, control and plant rooms
  • All areas [not mentioned] deemed by Risk Assessment
  • Manual release controls for electronically locked doors
  • Escape equipment for disable people
  • Refuges and call points

Coleman Electronics Ltd carry out audits on existing systems and can provide annual and quarterly maintenance contracts to satisfy the owners statutory obligations for the maintenance of the emergency lighting systems on their premises.